SAVECONFIG
Save current configuration in NVM
Platform: |
OEM719, OEM729, OEM7500, OEM7600, OEM7700, OEM7720, PwrPak7, CPT7, CPT7700, SMART7, SMART2 |
SAVECONFIG saves commands that were entered by a user to establish the desired receiver configuration on start up. This configuration is saved in Non-Volatile Memory (NVM) and is executed every time the receiver starts, whether by power-up or the RESET command. The commands that are saved as part of a configuration are typically LOG requests, SERIALCONFIG commands, ICOMCONFIG commands, a FIX command and others. Note that not all the commands can be saved using SAVECONFIG. All of the commands that set a configuration, including default commands for the receiver, are listed in the RXCONFIG log. To clear the commands saved by SAVECONFIG and reset the receiver to the factory-set configuration, the FRESET command can be used.
For commands that configure hardware, there is a delay between power being applied and the saved configuration being restored.
If using the SAVECONFIG command in NovAtel Connect, ensure that you have all windows other than the Console window closed. Otherwise, log requests used for the various windows are saved as well. This will result in unnecessary data being logged.
Message ID: 19
Abbreviated ASCII Syntax:
SAVECONFIG
Field |
Field Type |
ASCII Value |
Binary Value |
Description |
Format |
Binary Bytes |
Binary Offset |
---|---|---|---|---|---|---|---|
1 |
Command header |
- |
- |
SAVECONFIG header This field contains the command name for abbreviated ASCII or the message header for ASCII (see page 1) or Binary (see page 1). |
- |
H |
0 |