BASEANTENNAPCV

Sets the PCV model of the base receiver

Platform:

OEM719, OEM729, OEM7500, OEM7600, OEM7700, OEM7720, PwrPak7, CPT7, CPT7700, SMART7

Use the BASEANTENNAPCV command to set the Phase Center Variation (PCV) for a given frequency on the remote base receiver from which this receiver is receiving corrections. The Phase Center Variation entries follow the NGS standard and correspond to the phase elevation at 5 degree increments starting at 90 degrees and decreasing to 0.

Message ID: 1416

Abbreviated ASCII Syntax:

BASEANTENNAPCV Frequency [PCVArray [CorrectionType [StationId]]]

ASCII Example:

BASEANTENNAPCV GPSL1 0.00 -0.020 -0.07 -0.15 -0.24 -0.34 -0.43 -0.51 -0.56 -0.61 -0.65 -0.69 -0.69 -0.62 -0.44 -0.13 0.28 0.70 1.02

Field

Field Type

ASCII Value

Binary Value

Description

Format

Binary Bytes

Binary Offset

1

Command header

-

-

BASEANTENNAPCV header

This field contains the command name for abbreviated ASCII or the message header for ASCII (see page 1) or Binary (see page 1).

-

H

0

2

Frequency

See Table: Frequency Type

The frequency for which the phase center variations are valid.

Enum

4

H

3

PCVArray

 

NGS standard 19 element array of phase center variations, in millimetres, in 5 degree elevation increments from 90 to 0. Defaults to zero for all elevation increments.

Double [19]

152

H+4

4

CorrectionType

See Table: RTK Source Type

Correction type
(default = AUTO)

Enum

4

H+156

5

StationID

Char [8] or ANY

ID string
(default = ANY)

Char

8

H+160