BASEANTENNAPCV
Sets the PCV model of the base receiver
Platform: |
OEM719, OEM729, OEM7500, OEM7600, OEM7700, OEM7720, PwrPak7, CPT7, CPT7700, SMART7 |
Use the BASEANTENNAPCV command to set the Phase Center Variation (PCV) for a given frequency on the remote base receiver from which this receiver is receiving corrections. The Phase Center Variation entries follow the NGS standard and correspond to the phase elevation at 5 degree increments starting at 90 degrees and decreasing to 0.
Message ID: 1416
Abbreviated ASCII Syntax:
BASEANTENNAPCV Frequency [PCVArray [CorrectionType [StationId]]]
ASCII Example:
BASEANTENNAPCV GPSL1 0.00 -0.020 -0.07 -0.15 -0.24 -0.34 -0.43 -0.51 -0.56 -0.61 -0.65 -0.69 -0.69 -0.62 -0.44 -0.13 0.28 0.70 1.02
Field |
Field Type |
ASCII Value |
Binary Value |
Description |
Format |
Binary Bytes |
Binary Offset |
1 |
Command header |
- |
- |
BASEANTENNAPCV header This field contains the command name for abbreviated ASCII or the message header for ASCII or Binary. |
- |
H |
0 |
2 |
Frequency |
The frequency for which the phase center variations are valid. |
Enum |
4 |
H |
||
3 |
PCVArray |
|
NGS standard 19 element array of phase center variations, in millimetres, in 5 degree elevation increments from 90 to 0. Defaults to zero for all elevation increments. |
Double [19] |
152 |
H+4 |
|
4 |
CorrectionType |
Correction type |
Enum |
4 |
H+156 |
||
5 |
StationID |
Char [8] or ANY |
ID string |
Char |
8 |
H+160 |