STEADYLINEDIFFERENTIALTIMEOUT

Sets how long the receiver will report RTK/PPP after corrections are lost

Platform:

OEM719, OEM729, OEM7500, OEM7600, OEM7700, OEM7720, PwrPak7, CPT7, CPT7700, SMART7

Use this command to set how long STEADYLINE will report RTK or PPP solutions after a loss of corrections. If able, STEADYLINE will report an RTK or PPP solution until this timeout expires or until the RTK/PPP timeout expires, whichever is higher.

For example:

  • If the RTKTIMEOUT is 60 seconds and the STEADYLINEDIFFERENTIALTIMEOUT is 300 seconds, STEADYLINE will report an RTK solution for 300 seconds.

  • If the RTKTIMEOUT is 60 seconds and the STEADYLINEDIFFERENTIALTIMEOUT is 30 seconds, STEADYLINE will report an RTK solution for 60 seconds.

Message ID: 2002

Abbreviated ASCII Syntax:

STEADYLINEDIFFERENTIALTIMEOUT timeout

Factory Default:

STEADYLINEDIFFERENTIALTIMEOUT 60

ASCII Example:

STEADYLINEDIFFERENTIALTIMEOUT 300

Field

Field Type

ASCII Value

Binary Value

Description

Format

Binary Bytes

Binary Offset

1

Command header

-

-

STEADYLINEDIFFERENTIALTIMEOUT header

This field contains the command name for abbreviated ASCII or the message header for ASCII or Binary.

-

H

0

2

timeout

5 to 1200

Timeout period in seconds

Float

4

H