PPPTIMEOUT
Sets the maximum age of the PPP corrections
Platform: |
OEM719, OEM729, OEM7500, OEM7600, OEM7700, OEM7720, PwrPak7, CPT7, CPT7700, SMART7, SMART2 |
This command sets the maximum age of the corrections that can be used to generate a PPP solution.
By default, the delay is 360 seconds. If the received corrections are older than the delay time set, the receiver will not produce a PPP solution.
For example, if L-Band tracking (which is providing us the PPP corrections) is lost for some reason, the receiver will continue generating a PPP solution using last available corrections until the age of corrections is older than the delay time. Note that using older corrections degrades the PPP solution quality.
Message ID: 1560
Abbreviated ASCII Syntax:
PPPTIMEOUT delay
Factory Default:
PPPTIMEOUT 360
ASCII Example:
PPPTIMEOUT 120
Field |
Field Type |
ASCII Value |
Binary Value |
Description |
Format |
Binary Bytes |
Binary Offset |
1 |
Command header |
- |
- |
PPPTIMEOUT header This field contains the command name for abbreviated ASCII or the message header for ASCII or Binary. |
- |
H |
0 |
2 |
delay |
5 to 900 s |
Maximum corrections age |
Ulong |
4 |
H |