TRACKSIGNAL

Enable or disable tracking of a signal

Platform:

OEM719, OEM729, OEM7500, OEM7600, OEM7700, OEM7720, PwrPak7, CPT7, CPT7700, SMART7, SMART2

Use this command to enable or disable tracking of a signal within the channel configuration signal list.

Primary signals (LBAND and L1/E1/B1I signals) can not be disabled using the TRACKSIGNAL command.

Channel configurations containing the B2 signal will either track B2I or B2a signals corresponding to the availability of BeiDou Phase II and Phase III satellites respectively. Due to this, using the BEIDOUB2 option will toggle tracking for both B2I and B2a signals.

By default, the receiver attempts to track all signals in the channel configuration without needing a TRACKSIGNAL command. The channel configuration can be determined from the CHANCONFIGLIST log.

Message ID: 2311

Abbreviated ASCII Syntax:

TRACKSIGNAL signal track

Abbreviated ASCII Example:

TRACKSIGNAL GPSL2C DISABLE

Field

Field Type

ASCII Value

Binary Value

Description

Format

Binary Bytes

Binary Offset

1

Command header

TRACKSIGNAL header

This field contains the command name for abbreviated ASCII or the message header for ASCII or Binary.

H

0

2

signal

See Table: Signal

The signal to enable or disable

The signal is expected to match a signal in the current channel configuration.

Enum

4

H

3

track

DISABLE

0

Disable tracking of the signal

Enum

4

H+4

ENABLE

1

Enable tracking of the signal

Signal

Binary

ASCII

1

GPSL2

2

GPSL2P

3

GPSL2C

4

GPSL5

5

GPSL1C

6

SBASL5

7

GLOL2

8

GLOL2P

9

GLOL2C

10

GLOL3

11

GALE5A

12

GALE5B

13

GALALTBOC

14

GALE6

15

QZSSL2C

16

QZSSL5

17

QZSSL1C

18

QZSSL6

19

BEIDOUB1C

20

BEIDOUB2

21

BEIDOUB3

22

BEIDOUB2B