FILEAUTOTRANSFER

Enables/Disables automatic file transfer

Platform:

PwrPak7

PwrPak7M variants do not support this command.

Use this command to configure the automatic transfer function from internal memory to an external USB stick. If the mode is set to COPY or MOVE, all log files, except the file currently being logged to, will be automatically transferred to a USB stick when the USB stick is inserted.

This command will transfer all recorded log files to the USB stick provided the USB stick has enough free space to hold all the data. Files too large to fit in the remaining space on the USB stick are skipped.

The command must be issued before the USB stick is inserted. If the command is not issued first, the USB stick must be removed and reinserted to trigger the auto transfer.

The status of the transfer can be viewed by logging the FILETRANSFERSTATUS log.

A transfer in progress can be canceled by issuing the FILETRANSFER CANCEL command.

The settings for this command can be saved using the SAVECONFIG command.

Message ID: 2135

Abbreviated ASCII Syntax:

FILEAUTOTRANSFER [TransferMode]

ASCII Example:

FILEAUTOTRANSFER COPY

Field

Field Type

ASCII Value

Binary Value

Description

Binary Format

Binary Bytes

Binary Offset

1

Command header

-

-

FILEAUTOTRANSFER header

This field contains the command name for abbreviated ASCII or the message header for ASCII (see page 1) or Binary (see page 1).

-

H

0

2

TransferMode

1

OFF

Automatic copy/move is disabled (default)

Ulong

4

H

2

COPY

Automatically copies all files

3

MOVE

Automatically copies all files and then deletes them from internal memory after a successful copy

For the fastest transfer of files to an external memory stick, it is recommended that logging to a file be stopped.