SMART7 Strobe Specifications

The SMART7 strobe signals are available on the 14-Pin Interface connector. Pulse Per Second (PPS) strobes provide synchronization signal.

SMART7 Strobes Description

Strobes

Input/Output

Comment

Emulated Radar (ER)

Output

0VDC to VBATT+

Use the RADARCONFIG command to configure ER.

Emulated Radar pulses are output through the SMART Antenna Interface Cable (Optional Accessory) and the RADARSTATUS log.

PPS

Output

3.3V CMOS

A time synchronization output. This is a pulse where the leading edge is synchronized to receiver calculated GNSS Time. The polarity, period and pulse width can be configured using the PPSCONTROL command.

 

OM-20000167 v14