OEM-IMU-ADIS-16488 SPI Connection

The following table shows the connections required when connecting the OEM-IMU-ADIS-16488 IMU to a SPI compatible OEM7 receiver, such as the OEM7600, OEM7700 or OEM7720.

Receiver to ADIS-16488 Pin Connections

ADIS‑16488

Receiver

 

Pin

Pin Name

Pin

Pin Name

Description

1

NC

Do not connect

2

NC

Do not connect

3

SCLK

44

SPI_SCLK

SPI Serial Clock

4

SDO

43

SPI_MISO

SPI Data Output

5

SDI

41

SPI_MOSI

SPI Data Input

6

/CS

42

SPI_nCS

SPI Chip Select

7

DIO1

26

EVENT_OUT2

Synchronization signal

8

/RST

Reset IMU

RST must be high for the IMU to be active.

To enable the IMU when the receiver is powered on, connect this pin to Pin 1 or Pin 2 of the receiver interface connector through a 10 kΩ resistor (recommended).

Can also connect this pin to any stable 3.3 VDC power supply or output configuration to have more control over when IMU is enabled. When using this configuration note that:

  • pin 8 must be pulled low for greater than 100 ms to properly soft-reset the IMU

  • pin has an internal pull-up resistor

9

DIO2

29

EVENT_IN2

Data ready

10

VDD

3.3 VDC power supply

11

VDD

3.3 VDC power supply

12

VDD

3.3 VDC power supply

13

GND

Digital ground

14

GND

Digital ground

15

GND

Digital ground

16

NC

Do not connect

17

NC

Do not connect

18

NC

Do not connect

19

NC

Do not connect

20

NC

Do not connect

21

NC

Do not connect

22

NC

Do not connect

23

NC

Do not connect

24

NC

Do not connect

For the location of the receiver pins, refer to OEM7600 Interface Connector, OEM7700 Interface Connector or OEM7720 Interface Connector.

For more information about connecting using a SPI port, refer to Connect an OEM-IMU-ADIS-16488 Directly to an OEM7 Receiver Card.

 

OM-20000167 v12

July 2019

Email comments to NovAtel_TPUBS@NovAtel.com