Ports Configuration

Click the Ports tab to open the Ports configuration window. The communication ports that are currently configured are listed on the Ports page. Ports that are not listed can be configured by clicking the '+' icon.

Use the Ports configuration window to configure the communication ports on the receiver. The Ports configuration window is also used to configure the logs that are output from a specific communications port.

To add a port, set the Input Format, Port, Output Format and Messages parameters for the blank entry. To edit a port, change the parameters of an existing port configuration.

Input Format

The input format sets the type of message the port will accept. To set the input format, click the Input Format drop menu and select the format to use.

Auto

Set the port to automatically detect the format of the incoming RTK corrections.

CMR

Set the port to accept RTK correction messages in CMR format.

NONE

Disable input on the port.

NOVATEL

Set the port to accept NovAtel commands.

NOVATELX

Set the port to accept RTK correction messages in NOVATELX format.

RTCA

Set the port to accept RTK correction message in RTCA format.

RTCM

Set the port to accept RTK correction messages in RTCM format.

RTCMV3

Set the port to accept RTK correction messages in RTCM Version 3.0 format.

VERIPOS

Set the port to accept PPP correction messages over IP.

The MarinePak7 does not support Veripos correction messages over IP.

Port

There are several types of communication port that can be configured.

The MarinePak7 does not support COM4, COM5 or USB ports.

COM port

A COM port is a serial communication port. The number of COM ports available varies depending on the type of receiver. To add a COM port configuration:

  1. Click the Port drop menu and select the COM port to configure.

  2. Click the settings icon () and set the communication parameters to match the device connected to the port.

  3. Click the Baud Rate drop list and then click the baud rate (bps) used by this serial port. The default baud rate is 9600.

  4. Click N, E or O to select the parity used by this serial port.

    N = No parity, E = Even parity, O = Odd parity

    The default parity is N (No Parity).

  5. Click 7 or 8 to select the number of data bits used for each data message transmitted. The default is 8 bits.

  6. Click 1 or 2 to select the number of stops bits used for each data message transmitted.

  7. After setting the communication parameters, click the Done button to save the new settings.

ICOM

ICOM ports are virtual ports used for Ethernet or Wi-Fi connections. To add an ICOM port:

  1. Click the Port drop menu and select the ICOM port to configure.

  2. Click the settings icon () and set the communication parameters used for the ICOM port.

  3. In the Domain box, enter the hostname or IP address of the device

  4. In Port box, enter the TCP/UDP port number used by this ICOM port.

  5. Click one of the following buttons to select the protocol used by this ICOM port.

    • Disabled – Disable this ICOM port.

    • TCP – Use raw TCP on this port.

    • UDP – Use raw UDP on this port.

  6. After setting the communication parameters, click the Done button to save the new settings.

NCOM

Network ports are used when the receiver is acting as an NTRIP server or client. The receiver must have an Ethernet connection to use NCOM ports.

To add a NCOM port:

  1. Click the Port drop menu and select the NCOM port to configure.

  2. Click the settings icon () and set the communication parameters used for the NCOM port.

  3. In the Domain box, enter the hostname or IP address of the Endpoint.

  4. In the Port box, enter the TCP/UDP port number of the Endpoint.

  5. Click the Search for mountpoint button.

  6. Click the Mountpoint drop menu and click the mountpoint to use.

  7. In the Username box, enter the login user name. The username can be up to character 30 characters long.

  8. In the Password box, enter the login password. The Password can be up to 30 characters long.

  9. Click the Done button.

  10. After setting the communication parameters, click the Done button to save the new settings.

USB

A USB port is used to communicate with a device using a USB cable. To add a USB port, click the Port drop menu and select one of the USB ports.

Output Format

The output format sets the type of message the port will send. To set the output format, click the Output Format drop menu and select the format to use.

CMR

Set the receiver to send RTK correction messages in CMR format.

NMEA

Set the port to send NMEA format logs.

NONE

Disable output on the port.

NOVATEL

Set the port to send NovAtel logs.

NOVATELX

Set the receiver to send RTK correction messages in NOVATELX format.

RTCA

Set the receiver to send RTK correction messages in RTCA format.

RTCM

Set the receiver to send RTK correction messages in RTCM format.

RTCMV3

Set the receiver to send RTK correction messages in RTCM Version 3.0 format.

Messages

The Messages box shows the logs being sent out of this port.

To add a log:

  1. Click the Messages box and start typing the name of the log to add.

    A list of logs that start with the letters typed appears.

  2. Click the name of the log to add.

Message Settings

To edit the collection parameters of the log:

  1. Click the settings icon ().
    The Message Settings dialog box appears.


  2. Adjust the setting for the log.

    To change the logging settings for a log, select the parameter from the drop menus beside the log.

    Format

    Click ASCII, Binary or Abbr ASCII to select the format in which this log is generated.

    Trigger

    The trigger determines when the log is generated. Only triggers valid for the log are shown.

    • ONTIME

      Outputs the log at a regular interval. The number of seconds between log generation is set in the Period option.

    • ONCHANGED

      Outputs the current message and then continues to output when the message is changed.

    • ONCE

      Outputs the current message. If no message is currently present, the next message is output when available.

    • ONNEW

      Does not output the current message, but outputs when the message is updated (not necessarily changed).

    • ONALL

      Outputs the current message and then continues to output when the message is updated (not necessarily changed).

      The ONALL trigger is available on firmware versions 7.09.01 and higher.

    The triggers available depend on the log type.

    Log Type Triggers

    Type

    Recommended Trigger

    Illegal Triggers

    Synch

    ONTIME

    ONNEW, ONCHANGED

    Asych

    ONCHANGED or ONCE

    Polled

    ONCE or ONTIME

    ONNEW, ONCHANGED

    Period

    The log period (for ONTIME trigger) in seconds.

    Valid values for the high rate logging are 0.01, 0.02, 0.05, 0.1, 0.2, 0.25 and 0.5. For logging slower than once per second, any integer value is accepted.

    If the value entered is lower than the minimum measurement period, the value will be rejected.

  3. Repeat these steps to adjust the message settings for each log being collected.

  4. Click the Apply button to save the changes for all of the logs.

Message Settings NMEA Logs

To edit the collection parameters of a NMEA log:

  1. Click the settings icon ().
    The Message Settings dialog box appears.

  2. Select the NMEA Log Prefix option for this log.

    • GP

      The NMEA log will have prefix of GP and the NMEA log will include information only about the GPS satellites, even when the receiver is tracking multiple constellations.

    • Auto

      The NMEA log prefix changes as per the constellations enabled on the receiver. When there is one constellation in the solution and SPAN is disabled, the NMEA Talker ID is output as: GP for GPS, GL for GLONASS, GA for Galileo, and GB/BD for BeiDou. If more than one constellation is in the solution, the prefix is GN with the exception of GPGSV.

  3. If Auto was selected as the NMEA Log Prefix, select the BeiDou Log Prefix.

    • Select GB to use the current NMEA ID for BeiDou.

    • Select BD to use the legacy NMEA ID for BeiDou.

  4. Click one of the Precision buttons to select the number of decimal places used for the latitude and longitude values in this log.

  5. Click one of the Quality Indicator buttons to select the quality indicator that will be used for this log.

  6. Click the Trigger drop menu and select the trigger used for the log.

  7. Enter the log Period in seconds.

    Valid values for the high rate logging are 0.01, 0.02, 0.05, 0.1, 0.2, 0.25 and 0.5. For logging slower than once per second, any integer value is accepted. If the value entered is lower than the minimum measurement period, the value will be rejected.

  8. Set the Trigger and Period for each NMEA log.

  9. Click the Apply button to save the changes for all of the logs.

To remove a log from this port, click the X icon on the button for the log.

Click the Apply button to save the configuration on the receiver.