SMART Antenna Interface Cable (Optional Accessory)
The NovAtel part number for the SMART Antenna interface cable is 01019944. This cable provides access to all of the signals available on the SMART Antenna 14-pin Tyco Ampseal connector. The exposed wires (BATT+ and BATT-) can then be connected to a vehicular power circuit (or equivalent) protected by a 5 A slow blow fuse (user supplied).
The following SMART Antennas use this cable:
-
SMART7
-
SMART7 with RELAY7
-
SMART2
The SMART Antenna interface cable is also compatible with the Ag-Star, SMART6 and SMART6-L.
In the following diagram, the dimensions are in millimetres.
This cable is also used when the RELAY7 is connected to the SMART7. When the RELAY7 is connected to the SMART7, PPS and COM3 are not available.
Signal Name |
J1 |
J2 |
J3 |
J4 |
J5 |
E1 |
E2 |
---|---|---|---|---|---|---|---|
COM1-TXD |
1 |
2 |
|
|
|
|
|
COM1-RXD |
2 |
3 |
|
|
|
|
|
COM2-TXD |
3 |
|
2 |
|
|
|
|
COM2-RXD |
4 |
|
3 |
|
|
|
|
COM3-TXD |
8 |
|
|
2 |
|
|
|
COM3-RXD |
13 |
|
|
3 |
|
|
|
CAN+ |
6 |
|
|
|
7 |
|
|
CAN- |
7 |
|
|
|
2 |
|
|
SIGGND |
5 |
5 |
|
|
|
|
|
SIGGND |
5 |
|
5 |
|
|
|
|
SIGGND |
5 |
|
|
5 |
|
|
|
SIGGND |
5 |
|
|
|
3 |
|
|
SIGGND |
5 |
|
|
|
|
|
SIGGND |
EMD RADAR OUT (E2) |
10 |
|
|
|
|
|
ER_OUT |
RELAYO1/MARK INPUT (E2)1 |
11 |
|
|
|
|
|
MKI |
PPS/RLYO2 (E2) |
12 |
|
|
|
|
|
PPS |
PWR RET (GND) (E1) |
9 |
|
|
|
|
BATT- |
|
PWR INPUT (E1) |
14 |
|
|
|
|
BATT+ |
|
Signal Name |
Signal Specifications |
---|---|
CAN |
SAE J1939/ ISO 11783/ ISO 11898 Compatible |
PPS Output |
3.3 V CMOS Logic Compatible |
Ground Speed Output |
High= Supply Voltage Maximum Low= 1.5 V Maximum Load= 3K Ohm Minimum |
SMART Antenna Custom Cable Recommendation
To create a custom cable for a SMART Antenna, a specific connector is required on the end of the cable. See the following table for information about this connector.
Connector |
Description |
Commercial Part Number |
---|---|---|
J1 |
AMP Seal 14-pin Plug |
776273-1 |