SMART7 Environmental and Electrical Specifications
Operating Temperature |
-40°C to +70°C |
Storage Temperature |
-45°C to +80°C |
Humidity |
MIL-STD-810G(CH1), Method 507.6 |
Immersion |
MIL-STD-810G(CH1), Method 512.6 |
Ingress Protection Rating |
IP67 IP69 IP67 and IP69 ratings require that the cable is connected to the SMART7. |
Shock |
MIL-STD-810G(CH1), Method 516.7 |
Solar Radiation |
IEC 60950-22 8.2, ISO 9022-9, Method 20, Severity Degree 03 |
Salt Fog |
IEC 60068-2-11 |
Sand and Dust |
MIL-STD-810G(CH1), Method 510.5 |
Random Vibration |
MIL-STD-810G(CH1), Method 514.7 |
Voltage |
+7 to +30 VDC |
Power Consumption |
4 W typical, value for GPS L1/L2 These are typical values using serial ports without interference mitigation. These values can change with the number of satellites in view, firmware version, data logging rates and features in use. Use them as a guide for what you might expect but not as absolute values |