These specifications apply to the SMART2, SMART2-B and SMART2-TB.

SMART2 environmental specifications

Environment

Operating temperature

-40°C to +70°C

Storage temperature

-45°C to +75°C

Humidity

MIL-STD-810G(CH1), Method 507.6

Immersion

MIL-STD-810G(CH1), Method 512.6

Ingress protection rating

IP67 and IP69 per IEC 60529

IP67 and IP69 ratings require that the cable is connected to the SMART2.

Shock

MIL-STD-810G(CH1), Method 516.7

Solar radiation

IEC 60950-22 8.2

MIL-STD-810G(CH1), Method 505.6

Salt fog

IEC 60950-22 8.3

MIL-STD-810G(CH1), Method 509.6

Sand and dust

MIL-STD-810G(CH1), Method 510.6

Random vibration

MIL-STD-810G(CH1), Method 514.7

Altitude

MIL-STD-810G(CH1), Method 500.6

Acidic environment

MIL-STD-810G(CH1), Method 518.2

Contamination by fluids

MIL-STD-810G, Method 504.2

Mechanical bump

IEC 60068-2-27 Test Ea

Transit drop (packaged)

MIL-STD-810G(CH1), Method 516.7

Transit drop (unpackaged)

IEC 60068-2-31 Test Ec

SMART2 power requirements

Power

Voltage / current

+7 to +30 VDC / 500 mA

Power consumption

2.5 W typical, value for GPS L1/L2