OEM719 Strobe Specifications

OEM719 Strobe Description

Strobes

Input/Output

Factory Default

Comment

Event1 (Mark 1)

Input

Leading edge triggered

Active low

An input mark for which a pulse greater than 150 ns triggers certain logs to be generated. (Refer to the MARKPOS and MARK1TIME logs and ONMARK trigger.) Polarity is configurable using the EVENTINCONTROL command. The mark inputs have 10K pull-up resistors to 3.3 V

Event1 is the default behavior for pin 9 of connector P1701. The secondary behavior for pin 9 is COM3_Tx. If COM3 is enabled, the Event1 input is disabled.

Event2 (Mark 2)

Input

Leading edge triggered

Active low

An input mark for which a pulse greater than 150 ns triggers certain logs to be generated (see the MARK2POS and MARK2TIME logs). Polarity is configurable using the EVENTINCONTROL command. The mark inputs have 10K pull-up resistors to 3.3 V

Event2 is the default behavior for pin 7 of connector P1701. The secondary behavior for pin 7 is CAN1Tx. If CAN1 is enabled, the Event2 input is disabled.

PPS

Output

Active low

A time synchronization output. This is a pulse where the leading edge is synchronized to receiver-calculated GNSS Time. The polarity, period and pulse width can be configured using the PPSCONTROL command

PV
(Position Valid)

Output

Active high

Indicates a valid GNSS position solution is available.

nRESET_IN

Input

Active low

Reset signal input from external system; active low.

This pin must be held low for >20 µs while stable power is already applied, to reset the OEM719 card.

It is recommended to hold the nRESET_IN pin low for a >150 ms when initially applying power to the card, giving the power supply time to stabilize before the card starts to boot.

VARF (Variable Frequency)

Output

Active low

A programmable variable frequency output ranging from 0 - 50 MHz (refer to the EVENTOUTCONTROL command)

VARF is the default behavior for pin 6 of connector P1701. The secondary behavior for pin 6 is CAN1Rx. If CAN1 is enabled, the VARF output is disabled.

OEM719 Strobe Electrical Specification

Strobe

Symbol

Min
(V)

Typ
(V)

Max
(V)

Current
(mA)

Event1 (Mark1)

Event2 (Mark2)

VIL

 

 

0.7

-

VIH

2.1

 

 

PPS

VOL

 

 

0.4

16

VOH

2.4

 

 

PV

VOL

 

 

0.4

4

VOH

2.9

 

 

nRESET_IN

VIL

 

 

0.8

-

VIH

2.3

 

 

VARF

VOL

 

 

0.4

4

VOH

2.9