GT7800 Strobe Specifications
The GT7800 strobe signals are available on the EVENT BNC connectors.
Strobes |
Input/Output |
Factory Default |
Comment |
EVENT_IN1 |
Input Leading edge triggered |
Active low |
Input mark for which a pulse greater than 150 ns triggers certain logs to be generated. (Refer to the MARKPOS log, MARK1TIME log, and ONMARK trigger.) Polarity is configurable using the EVENTINCONTROL command. 50 Ω nominal impedance 1 GHz maximum |
EVENT_OUT2 |
Output |
Active low |
Programmable variable frequency outputs ranging from 0 Hz to 50 MHz (refer to the EVENTOUTCONTROL command). |
EVENT IN 2 and EVENT OUT 1 are not active.
Strobe |
Sym |
Min |
Max |
Current |
EVENT_IN1 |
VIL |
- |
0.8 |
<±1 mA |
VIH |
2.0 |
6.0 |
||
EVENT_OUT2 |
VOL |
- |
0.4 |
±6 mA |
VOH |
2.0 |
3.3 |
All signal I/O are at LVCMOS levels.