OEM-IMU-ISA-100C IMU to UIC Cable Assembly
The NovAtel part number for the OEM-IMU-ISA-100C IMU to UIC interface cable is 01019393 (Figure: OEM-IMU-ISA-100C IMU to UIC Cable Assembly). This cable provides power to the IMU and enables communication between the UIC and the IMU.
J2 Pin |
Signal |
J1 Pin |
1 |
GND |
9 |
2 |
3.3 V |
1 |
3 |
GND |
4 |
4 |
GND |
5 |
5 |
GND |
6 |
6 |
GND |
8 |
7 |
GND |
10 |
8 |
GND |
15 |
9 |
GND |
16 |
10 |
GND |
21 |
11 |
GND |
22 |
12 |
5.25 V |
43 |
13 |
-5.25 V |
49 |
14 |
-5.25 V |
50 |
15 |
-5.25 V |
|
16 |
15 V |
7 |
17 |
3.3 V |
3 |
18 |
GND |
28 |
19 |
– |
– |
20 |
– |
– |
21 |
NOGOx |
18 |
22 |
– |
– |
23 |
GND |
29 |
GND |
35 |
|
24 |
TXC+ |
32 |
25 |
SYNC- |
34 |
26 |
GND |
41 |
27 |
TXD+ |
40 |
28 |
– |
– |
29 |
GND |
42 |
30 |
5.25 V |
44 |
31 |
3.3 V |
2 |
32 |
3.3 V |
|
33 |
PWRDOWNx |
12 |
34 |
RESETIMUx |
14 |
35 |
– |
– |
36 |
GND |
45 |
37 |
– |
– |
38 |
TXC- |
30 |
39 |
GND |
48 |
40 |
SYNC+ |
36 |
41 |
TXD- |
38 |
42 |
– |
– |
43 |
GND |
48 |
44 |
5.25 V |
46 |