IMU-µIMU-IC Electrical and Environmental

IMU-µIMU-IC Electrical Specifications

Electrical

IMU power consumption

11 W (typical)

IMU input voltage

+10 to +34 VDC

Recommended fuse

1.8 A slow blow

IMU interface

RS-422

Connectors

Power

SAL M12, 5 pin, male

Data

SAL M12, 5 pin, female

Wheel Sensor

SAL M12, 8 pin, male

IMU-µIMU-IC Environmental Specifications

Environmental

Operating temperature

-40°C to +55°C

Storage temperature

-40°C to +71°C

Humidity

MIL-STD-810G(Ch1), Method 507.6

Random vibe

MIL-STD-810G(Ch1), Method 514.7 (2.0 g)

Environment

MIL-STD-810G(Ch1), Method 512.6

IEC 60529 IP67