IMU Enclosure Interface Cable
The NovAtel part number for the IMU Enclosure interface cable is 01019319 (see Figure: IMU Enclosure Interface Cable). This cable enables communication between the receiver and the IMU.
This cable is used for all versions of the IMU Enclosure (IMU-ISA-100C, IMU-LN200, IMU-HG1900 and IMU-µIMU-IC).
In the following diagram, the dimensions are in millimetres.
P1 Pinout |
Function |
J2 Pinout |
1 |
TX+ |
2 |
2 |
RX+ |
3 |
3 |
TX- |
8 |
4 |
RX- |
7 |
5 |
GND |
5 |
Shield |
Shield |
Shield |
Custom Cable Recommendations
The tables below provide recommendations for creating custom cables to replace the IMU Enclosure interface cable (01019319).
Connector |
Description |
---|---|
P1 |
M12x1, 5 position, male |
J2 |
DB-9, female |
IMU |
RS-422 |
---|---|
IMU-ISA-100C IMU-LN200 IMU-HG1900 IMU-µIMU-IC |
< 50 metres |