HG1700 Electrical and Environmental

HG17000 Electrical Specifications

Electrical

IMU power consumption

IMU-H58: 9 W (max)

IMU-H62: 8 W (max)

IMU input voltage

+12 to +28 VDC

Recommended fuse

1.0 A slow blow

Input/Output connectors

MIL-C-38999-III, 22 pin (all IMUs)

IMU interface

RS-232 or RS-422

HG17000 Environmental Specifications

Environmental (IMU)

Operating temperature

-30°C to +60°C (-22°F to 140°F)

Storage temperature

-45°C to +80°C (-49°F to 176°F)

Humidity

95% non-condensing