SETHEAVEWINDOW

Set Heave Filter Length

Platform: 

OEM719, OEM729, OEM7500, OEM7600, OEM7700, OEM7720, PwrPak7, CPT7, CPT7700

Use this command to control the length of the heave filter. This filter determines the heave (vertical displacement) of the IMU, relative to a long term level surface. This command does not control the DELAYEDHEAVE filter window.

Message ID: 1383

Abbreviated ASCII Syntax:

SETHEAVEWINDOW filterlength

Abbreviated ASCII Example:

SETHEAVEWINDOW 35

Field

Type

ASCII Value

Binary Value

Description

Binary
Format

Binary Bytes

Binary
Offset

1

Command header

-

-

SETHEAVEWINDOW header

This field contains the command name for abbreviated ASCII or the message header for ASCII (see page 1) or Binary (see page 1).

-

H

0

2

FilterLength

Integer
(1 – 300 s) (default = 20 s)

 

This filter length will be used in the heave filter. Typically, set the filter length to 5 x wave period

Long

4

H