Secure the CPT7 Using the Adapter Plate

The CPT7 Adapter Plate (01020112) allows the CPT7 to be installed using the mounting hole spacing designed for the SPAN-CPT or SPAN-IGM-A1/S1.

To secure a CPT7 using the Adapter Plate:

  1. Place the CPT7 on the Adapter Plate and align the mounting holes on the CPT7 with the threaded holes in the Adapter Plate.

  2. Secure the CPT7 to the Adapter Plate using the four screws (#6 - 32) included with the mounting plate.

  3. Secure the Adapter Plate to the mounting location using 4 screws.
    See Figure: CPT7 Adapter Plate for the adapter plate dimensions and mounting hole locations.

  4. If the CPT7 is replacing a SPAN-CPT or SPAN-IGM-S1, see Figure: Offset from the CPT7 to the SPAN-CPT or Figure: Offset from the CPT7 to the SPAN-IGM-S1 for the offset of the center of navigation of the previous system to the center of navigation of the CPT7.

 

CPT7 Adapter Plate

 

Offset from the CPT7 to the SPAN-CPT

Dimensions are in mm.

The axis marking on the CPT7 indicates the orientation of the X, Y and Z axis only. It does not indicate the center of navigation. For the location of the center of navigation, refer to Figure: CPT7/CPT7700 Center of Navigation.

Offset from the CPT7 to the SPAN-IGM-S1

Dimensions are in mm