SBAS1

PRN mask assignments

Platform:

OEM719, OEM729, OEM7500, OEM7600, OEM7700, OEM7720, PwrPak7, CPT7, CPT7700, SMART7, SMART2

The PRN mask is given in SBAS1. The transition of the PRN mask to a new one (which will be infrequent) is controlled with the 2-bit IODP, which sequences to a number between 0 and 3. The same IODP appears in the applicable SBAS2, SBAS3, SBAS4, SBAS5, SBAS7, SBAS24 and SBAS25 messages (SBAS32, SBAS33, SBAS34, SBAS35 and SBAS45). This transition would probably only occur when a new satellite is launched or when a satellite fails and is taken out of service permanently. A degraded satellite may be flagged as a “do not use” satellite temporarily.

Message ID: 977

Log type: Asynch

Recommended input:

log SBAS1a onchanged

ASCII example:

#SBAS1A,USB1,0,46.5,SATTIME,2209,514210.000,02000020,5955,16809;135,ffffffff0000000000000000000000002a40000000000000000000,2*193c8b8a

Each raw SBAS frame gives data for a specific frame decoder number. The SBAS1 message can be logged to view the data breakdown of SBAS frame 1 which contains information about the PRN mask assignment.

Field

Field type

Description

Format

Binary bytes

Binary offset

1

Log header

SBAS1 header

For information about log headers, see ASCII, Abbreviated ASCII or Binary.

 

H

0

2

prn

Source PRN of message

Ulong

4

H

3

mask

PRN bit mask

Uchar[27]

28 1

H+4

4

iodp

Issue of PRN mask data

Ulong

4

H+32

5

xxxx

32-bit CRC (ASCII and Binary only)

Ulong

4

H+36

6

[CR][LF]

Sentence terminator (ASCII only)

-

-

-