SAVEDSURVEYPOSITIONS

Saved surveyed positions

Platform:

OEM719, OEM729, OEM7500, OEM7600, OEM7700, OEM7720, PwrPak7, CPT7, CPT7700, SMART7

This log lists the surveyed positions saved on the receiver.

A surveyed position is saved using the AUTOSURVEY command or SURVEYPOSITION command.

The maximum number of surveys that can be saved to memory is 32. If this number is exceeded, the new position entry will overwrite the last entry reported by the SAVEDSURVEYPOSITIONS log.

Message ID: 1951

Log Type: Polled

Recommended Input:

log savedsurveypositions once

Abbreviated ASCII Example:

<SAVEDSURVEYPOSITIONS USB1 0 52.5 FINESTEERING 2209 514133.104 02000020 ddf2 16809

<     3

<          "MN01" 51.11600000000 -114.03800000000 1065.0000

<          "MN02" 55.11600000000 -114.03800000000 1065.0000

<          "MN03" 55.11600000000 -94.03800000000 65.0000

Field

Field Type

Description

Format

Binary Bytes

Binary Offset

1

Log header

SAVEDSURVEYPOSITIONS header

For information about log headers, see ASCII, Abbreviated ASCII or Binary.

 

H

0

2

#Positions

Number of records to follow.

Ulong

4

H

3

Position ID

ID for the saved position.

String[5]

4 or 81

H+4

4

Latitude

Latitude of the position

(-90 to 90 degrees) where a ‘-’ sign denotes south and a ‘+’ sign denotes north

Double

8

H+8 or
H+12

5

Longitude

Longitude of the position

(-360 to 360 degrees) where a ‘-’ sign denotes west and a ‘+’ sign denotes east

Double

8

H+16 or
H+20

6

Height

Mean Sea Level height of the position in metres

Double

8

H+24 or
H+28

7

Next reading offset = H+4+(#Positions * 28) or H+4+(#Positions * 32)

8

xxxx

32-bit CRC (ASCII and Binary only)

Hex

4

H+4+(#Positions * 28) or
H+4+(#Positions * 32)

9

[CR][LF]

Sentence terminator (ASCII only)

-

-

-