PASSTHROUGH

Redirected data from all ports

Platform:

OEM719, OEM729, OEM7500, OEM7600, OEM7700, OEM7720, PwrPak7, CPT7, CPT7700, SMART7, SMART2

This log outputs pass through data from all receiver ports. The behavior is the same as the port specific pass though logs described in PASSCOM, PASSAUX, PASSUSB, PASSICOM, PASSNCOM.

Message ID: 1342

Log Type: Asynch

Recommended Input:

log passthrougha onchanged

ASCII Example:

#PASSTHROUGHA,USB1,0,53.0,FINESTEERING,2209,509529.759,12000020,5fa3,16809;USB1,52,\xaaD\x12\x1c\xb2\x00\x00\xde\x14\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\xde\x00\x00\x00\x06\x00\x00\x00Sendhxdt\x00\x00\x00\x00\x19W\x10Z*72b6022f

Field

Field type

Description

Format

Binary Bytes

Binary Offset

1

Log header

PASSTHROUGH header

For information about log headers, see ASCII, Abbreviated ASCII or Binary.

 

H

0

2

Port

See Table: COM Port Identifiers

Enum

4

H

3

#bytes

Number of bytes to follow

Ulong

4

H+4

4

data

Message data

Char[80]

80

H+8

5

xxxx

32-bit CRC (ASCII and Binary only)

Ulong

4

H+8+#bytes

6

[CR][LF]

Sentence terminator (ASCII only)

-

-

-