PASSTHROUGH
Redirected data from all ports
Platform: |
OEM719, OEM729, OEM7500, OEM7600, OEM7700, OEM7720, PwrPak7, CPT7, CPT7700, SMART7, SMART2 |
This log outputs pass through data from all receiver ports. The behavior is the same as the port specific pass though logs described in PASSCOM, PASSAUX, PASSUSB, PASSICOM, PASSNCOM.
Message ID: 1342
Log Type: Asynch
Recommended Input:
log passthrougha onchanged
ASCII Example:
#PASSTHROUGHA,USB1,0,53.0,FINESTEERING,2209,509529.759,12000020,5fa3,16809;USB1,52,\xaaD\x12\x1c\xb2\x00\x00\xde\x14\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\xde\x00\x00\x00\x06\x00\x00\x00Sendhxdt\x00\x00\x00\x00\x19W\x10Z*72b6022f
Field |
Field type |
Description |
Format |
Binary Bytes |
Binary Offset |
---|---|---|---|---|---|
1 |
Log header |
PASSTHROUGH header For information about log headers, see ASCII, Abbreviated ASCII or Binary. |
|
H |
0 |
2 |
Port |
Enum |
4 |
H |
|
3 |
#bytes |
Number of bytes to follow |
Ulong |
4 |
H+4 |
4 |
data |
Message data |
Char[80] |
80 |
H+8 |
5 |
xxxx |
32-bit CRC (ASCII and Binary only) |
Ulong |
4 |
H+8+#bytes |
6 |
[CR][LF] |
Sentence terminator (ASCII only) |
- |
- |
- |