LOGLIST
List of system logs
Platform: |
OEM719, OEM729, OEM7500, OEM7600, OEM7700, OEM7720, PwrPak7, CPT7, CPT7700, SMART7, SMART2 |
This log lists which messages are currently being logged to each port and when. The following tables show the binary and ASCII output. See also the RXCONFIG log for a list of current command settings.
Message ID: 5
Log Type: Polled
Recommended Input:
log loglista once
Abbreviated ASCII Example:
<LOGLIST USB1 0 53.0 FINESTEERING 2209 508498.000 12000020 c00c 16809
< 32
< COM1 RXSTATUSEVENTA ONNEW 0.000000 0.000000 HOLD
< COM2 RXSTATUSEVENTA ONNEW 0.000000 0.000000 HOLD
< COM3 RXSTATUSEVENTA ONNEW 0.000000 0.000000 HOLD
< FILE RXSTATUSEVENTA ONNEW 0.000000 0.000000 HOLD
< USB1 RXSTATUSEVENTA ONNEW 0.000000 0.000000 HOLD
< USB1 ITDETECTSTATUSA ONCHANGED 0.000000 0.000000 NOHOLD
< USB1_30 RXCONFIGB ONCHANGED 0.000000 0.000000 HOLD
< USB1_30 SATVIS2B ONCHANGED 0.000000 0.000000 HOLD
< USB1_30 AVEPOSB ONCHANGED 0.000000 0.000000 HOLD
< USB1_30 RXSTATUSB ONTIME 1.000000 0.000000 HOLD
< USB1_30 INTERFACEMODEB ONCHANGED 0.000000 0.000000 HOLD
< USB1_30 ITDETECTSTATUSB ONTIME 1.000000 0.000000 HOLD
< USB1_30 FILESTATUSB ONTIME 1.000000 0.000000 HOLD
< USB1_30 PORTSTATSB ONTIME 1.000000 0.000000 HOLD
< USB1_30 INSPVAXB ONTIME 1.000000 0.000000 HOLD
< USB1_30 RXSTATUSEVENTB ONCHANGED 0.000000 0.000000 HOLD
< USB1_30 TIMEB ONTIME 1.000000 0.000000 HOLD
< USB1_30 BESTPOSB ONTIME 1.000000 0.000000 HOLD
< USB1_30 HWMONITORB ONTIME 1.000000 0.000000 HOLD
< USB1_30 TRACKSTATB ONTIME 1.000000 0.000000 HOLD
< USB1_30 LBANDTRACKSTATB ONTIME 1.000000 0.000000 HOLD
< USB1_30 INSPOSXB ONTIME 1.000000 0.000000 HOLD
< USB1_30 MODELFEATURESB ONCHANGED 0.000000 0.000000 HOLD
< USB2 RXSTATUSEVENTA ONNEW 0.000000 0.000000 HOLD
< USB3 RXSTATUSEVENTA ONNEW 0.000000 0.000000 HOLD
< ICOM1 RXSTATUSEVENTA ONNEW 0.000000 0.000000 HOLD
< ICOM2 RXSTATUSEVENTA ONNEW 0.000000 0.000000 HOLD
< ICOM3 RXSTATUSEVENTA ONNEW 0.000000 0.000000 HOLD
< ICOM4 RXSTATUSEVENTA ONNEW 0.000000 0.000000 HOLD
< ICOM5 RXSTATUSEVENTA ONNEW 0.000000 0.000000 HOLD
< ICOM6 RXSTATUSEVENTA ONNEW 0.000000 0.000000 HOLD
< ICOM7 RXSTATUSEVENTA ONNEW 0.000000 0.000000 HOLD
Do not use undocumented logs or commands. Doing so may produce errors and void your warranty.
Binary
Field |
Field type |
Description |
Format |
Binary Bytes |
Binary Offset |
1 |
Log header |
LOGLIST (binary) header For information about log headers, see ASCII, Abbreviated ASCII or Binary. |
|
H |
0 |
2 |
#logs |
Number of messages to follow, maximum = 80 |
Ulong |
4 |
H |
3 |
port |
Output port, see Table: Detailed Port Identifier |
Enum |
4 |
H+4 |
4 |
message |
Message ID of the log |
Ushort |
2 |
H+8 |
5 |
message type |
Bits 0-4 = Reserved Bits 5-6 = Format Bit 7 = Response Bit (see Message Responses) |
Char |
1 |
H+10 |
6 |
Reserved |
Char |
1 |
H+11 |
|
7 |
trigger |
0 = ONNEW |
Enum |
4 |
H+12 |
8 |
period |
Log period for ONTIME |
Double |
8 |
H+16 |
9 |
offset |
Offset for period (ONTIME trigger) |
Double |
8 |
H+24 |
10 |
hold |
0 = NOHOLD |
Enum |
4 |
H+32 |
11... |
Next log offset = H + 4 + (#logs x 32) |
||||
variable |
xxxx |
32-bit CRC |
Hex |
4 |
H+4+ (#logs x 32) |
ASCII
Field |
Field type |
Description |
Format |
1 |
Log header |
LOGLIST (ASCII) header For information about log headers, see ASCII, Abbreviated ASCII or Binary. |
|
2 |
#logs |
Number of messages to follow, maximum = 80 |
Long |
3 |
port |
Output port, see Table: Detailed Port Identifier |
Enum |
4 |
message |
Message name of log with no suffix for abbreviated ASCII, an A suffix for ASCII and a B suffix for binary |
Char [ ] |
5 |
trigger |
ONNEW |
Enum |
6 |
period |
Log period for ONTIME |
Double |
7 |
offset |
Offset for period (ONTIME trigger) |
Double |
8 |
hold |
NOHOLD |
Enum |
9... |
Next log |
||
variable |
xxxx |
32-bit CRC |
Hex |
variable |
[CR][LF] |
Sentence terminator |
- |