HWMONITOR
Monitor hardware levels
Platform: |
OEM719, OEM729, OEM7500, OEM7600, OEM7700, OEM7720, PwrPak7, CPT7, CPT7700, SMART7, SMART2 |
This log allows the user to monitor temperature, antenna current and voltages.
Message ID: 963
Log Type: Polled
Recommended Input:
log hwmonitora ontime 10
ASCII Example:
#HWMONITORA,USB1,0,51.5,FINESTEERING,2209,507561.000,02000020,52db,16809;10,59.218563080,100,0.000122100,200,3.302808285,600,5.165323734,700,1.189255238,800,3.301587343,f00,1.835775375,1100,5.161416531,1500,1.554945111,1700,59.218563080,1600*38415eae
Field |
Field Type |
Description |
Format |
Binary Bytes |
Binary Offset |
1 |
Log header |
HWMONITOR header For information about log headers, see ASCII, Abbreviated ASCII or Binary. |
|
H |
0 |
2 |
# measurements |
Number of measurements to follow |
Ulong |
4 |
H |
3 |
reading |
Temperature, antenna current or voltage reading Units:
|
Float |
4 |
H+4 |
4 |
status |
HexUlong |
4 |
H+8 |
|
5... |
Next reading offset = H + 4 + (# measurements x 8) |
||||
6 |
xxxx |
32-bit CRC (ASCII and Binary only) |
Hex |
4 |
H+4+(# measurements x 8) |
7 |
[CR][LF] |
Sentence Terminator (ASCII only) |
- |
- |
- |