GPZDA

UTC time and date

Platform:

OEM719, OEM729, OEM7500, OEM7600, OEM7700, OEM7720, PwrPak7, CPT7, CPT7700, SMART7, SMART2

The GPZDA log outputs the UTC date and time. If no valid almanac is stored in the receiver, a default UTC offset is used to generate the time until a new almanac is downloaded. If the offset is not up-to-date, this initial UTC time may be incorrect until the new almanac is present.

Message ID: 227

Log Type: Synch

Recommended Input:

log gpzda ontime 1

Example:

$GPZDA,204007.00,13,05,2022,,*62

See the Note in the GPGGA log that applies to all NMEA logs.

Field

Structure

Description

Symbol

Example

1

$GPZDA

Log header

 

$GPZDA

2

utc

UTC time status

hhmmss.ss

220238.00

3

day

Day, 01 to 31

xx

15

4

month

Month, 01 to 12

xx

07

5

year

Year

xxxx

1992

6

null

Local zone description—not available

Local time zones are not supported by OEM7 family receivers.
Fields 6 and 7 are always null.

xx

(empty when no data is present)

7

null

Local zone minutes description—not available

xx

(empty when no data is present)

8

*xx

Check sum

*hh

*6F

9

[CR][LF]

Sentence terminator

 

[CR][LF]