GPZDA
UTC time and date
Platform: |
OEM719, OEM729, OEM7500, OEM7600, OEM7700, OEM7720, PwrPak7, CPT7, CPT7700, SMART7, SMART2 |
The GPZDA log outputs the UTC date and time. If no valid almanac is stored in the receiver, a default UTC offset is used to generate the time until a new almanac is downloaded. If the offset is not up-to-date, this initial UTC time may be incorrect until the new almanac is present.
Message ID: 227
Log Type: Synch
Recommended Input:
log gpzda ontime 1
Example:
$GPZDA,204007.00,13,05,2022,,*62
See the Note in the GPGGA log that applies to all NMEA logs.
Field |
Structure |
Description |
Symbol |
Example |
1 |
$GPZDA |
Log header |
|
$GPZDA |
2 |
utc |
UTC time status |
hhmmss.ss |
220238.00 |
3 |
day |
Day, 01 to 31 |
xx |
15 |
4 |
month |
Month, 01 to 12 |
xx |
07 |
5 |
year |
Year |
xxxx |
1992 |
6 |
null |
Local zone description—not available Local time zones are not supported by OEM7 family receivers. |
xx |
(empty when no data is present) |
7 |
null |
Local zone minutes description—not available |
xx |
(empty when no data is present) |
8 |
*xx |
Check sum |
*hh |
*6F |
9 |
[CR][LF] |
Sentence terminator |
|
[CR][LF] |