LN-200 IMU in Universal Enclosure

Important! Assemble in accordance with applicable industry standards. Ensure all ESD measures are in place, in particular, use a ground strap before exposing or handling any electronic items, including the IMU. Take care to prevent damaging or marring painted surfaces, O-rings, sealing surfaces, and the IMU.

The following procedure provides the necessary information to install the LN-200 sensor into the Universal Enclosure (NovAtel part number 01018590), both illustrated below. The steps required for this procedure are:

  • Disassemble the Universal Enclosure

  • Install the LN-200 Sensor Unit

  • Reassemble the Universal Enclosure

Required Parts

Use thread-locking fluid on all fasteners except for the cable harness connectors.

 

Torque values for all fasteners, including those for the cable harness screws, are as follows:

  • Size 6-32: 0.79-0.90 N-m (7.0-8.0 lb-in)

  • Size M4: 1.36-1.58 N-m (12.0-14.0 lb-in)