USERI2CBITRATE

Set the communication rate for the User I2C bus

Platform:

OEM7600, OEM7700, OEM7720

Use this command to set the communication bit rate for the User I2C bus.

Message ID: 2383

Abbreviated ASCII Syntax:

USERI2CBITRATE BitRate

Factory Default:

USERI2CBITRATE 400K

ASCII Examples:

USERI2CBITRATE 100K

USERI2CBITRATE 400K

Field

Field Type

ASCII Value

Binary Value

Description

Format

Binary Bytes

Binary Offset

1

Command header

USERI2CBITRATE header

This field contains the command name for abbreviated ASCII or the message header for ASCII (see page 1) or Binary (see page 1).

H

0

2

BitRate

100K

1

Set the User I2C bus communication rate to 100 kbits/s.

Enum

4

H

400K

2

Set the User I2C bus communication rate to 400 kbits/s.