USERI2CBITRATE

Set the communication rate for the User I2C bus

Platform:

OEM7600, OEM7700, OEM7720

Use this command to set the communication bit rate for the User I2C bus.

Message ID: 2383

Abbreviated ASCII syntax:

USERI2CBITRATE BitRate

Factory default:

USERI2CBITRATE 400K

ASCII examples:

USERI2CBITRATE 100K

USERI2CBITRATE 400K

Field

Field type

ASCII value

Binary value

Description

Format

Binary bytes

Binary offset

1

Command header

USERI2CBITRATE header

This field contains the command name for abbreviated ASCII or the message header for ASCII or Binary.

H

0

2

BitRate

100K

1

Set the User I2C bus communication rate to 100 kbits/s.

Enum

4

H

400K

2

Set the User I2C bus communication rate to 400 kbits/s.