SOFTLOADSREC
Sends an S-Record to the receiver for the SoftLoad process
Platform: |
OEM719, OEM729, OEM7500, OEM7600, OEM7700, OEM7720, PwrPak7, CPT7, CPT7700, SMART7, SMART2 |
Use this command to send S-Records to the receiver for the SoftLoad process. Refer to Updating Using SoftLoad Commands for more information about the SoftLoad process.
After each SOFTLOADDATA command, the user must wait for the OK or ERROR command response before proceeding. This response is guaranteed to be output from the receiver within 15 seconds from the time the command was received by the receiver. If an error response is returned, consult the SOFTLOADSTATUS log for more detail.
This command can only be sent to the receiver when the SOFTLOADSTATUS log reports READY_FOR_SETUP or READY_FOR_DATA.
Message ID: 477
Abbreviated ASCII Syntax:
SOFTLOADSREC s-record
Input Example:
SOFTLOADSREC “S30900283C10FAA9F000EF”
Field |
Field Type |
ASCII Value |
Binary Value |
Description |
Format |
Binary Bytes |
Binary Offset |
1 |
Command header |
- |
- |
SOFTLOADSREC header This field contains the command name for abbreviated ASCII or the message header for ASCII (see page 1) or Binary (see page 1). |
- |
H |
0 |
2 |
s-record |
- |
ASCII S-Record string copites from firmware *.shex file |
String [515] |
variable1 |
H |
|
3 |
Reserved |
- |
1 |
Reserved. Set to 1 in the binary case |
Ulong |
4 |
variable |