SOFTLOADRESET
Initiates a new SoftLoad process
Platform: |
OEM719, OEM729, OEM7500, OEM7600, OEM7700, OEM7720, PwrPak7, CPT7, CPT7700, SMART7, SMART2 |
This command restarts the SoftLoad process. Refer to Updating Using SoftLoad Commands for more information about the SoftLoad process.
The command does not affect the flash and does not reset the receiver.
The SOFTLOADRESET command can be issued at any time. If it is issued while a SoftLoad process is currently in progress then that process is terminated and a new one is started. After the SOFTLOADRESET command is processed the SOFTLOADSTATUS log will report a status of READY_FOR_SETUP.
After issuing the SOFTLOADRESET command the user must wait for the OK or ERROR command response before proceeding. This response is guaranteed to be output from the receiver within 300 seconds from the time the command was received by the receiver. If an error response is returned, consult the SOFTLOADSTATUS log for more detail.
Message ID: 476
Abbreviated ASCII Syntax:
SOFTLOADRESET
Input Example:
SOFTLOADRESET
Field |
Field Type |
ASCII Value |
Binary Value |
Description |
Format |
Binary Bytes |
Binary Offset |
1 |
Command header |
- |
- |
SOFTLOADRESET header This field contains the command name for abbreviated ASCII or the message header for ASCII (see page 1) or Binary (see page 1). |
- |
H |
0 |
2 |
Reserved |
- |
- |
Reserved. Set to 1 in the binary case |
Enum |
4 |
H |