RTKSOURCETIMEOUT

Sets RTK correction source timeout

Platform:

OEM719, OEM729, OEM7500, OEM7600, OEM7700, OEM7720, PwrPak7, CPT7, CPT7700, SMART7

When multiple RTK correction sources are available, this command allows the user to set a time, in seconds, that the receiver will wait before switching to another RTK correction source if corrections from the original source are lost.

Message ID: 1445

Abbreviated ASCII Syntax:

RTKSOURCETIMEOUT option [timeout]

Factory Default:

RTKSOURCETIMEOUT AUTO

ASCII Example:

RTKSOURCETIMEOUT auto

RTKSOURCETIMEOUT set 180

Field

Field Type

ASCII Value

Binary Value

Description

Format

Binary Bytes

Binary Offset

1

Command header

-

-

RTKSOURCETIMEOUT header

This field contains the command name for abbreviated ASCII or the message header for ASCII (see page 1) or Binary (see page 1).

-

H

0

2

option

AUTO

1

Sets the timeout according to network type or other self-detected conditions.

Timeout field is optional for AUTO and has no effect

Enum

4

H

SET

2

Sets the timeout to the value entered in the timeout field.

3

timeout

1 to 3600 s (maximum)

Specify the time

0 is not accepted if SET is entered in the option field

(default=0 for the AUTO option)

Ulong

4

H+4