REFERENCESTATIONTIMEOUT
Sets timeout for removing previously stored base stations
|
Platform: |
OEM719, OEM729, OEM7500, OEM7600, OEM7700, OEM7720, PwrPak7, CPT7, CPT7700, SMART7 |
This command sets how long the receiver will retain RTK base station co-ordinates. Shorter durations might be required if the receiver is operating in a VRS RTK network that recycles base station IDs quickly.
Message ID: 2033
Abbreviated ASCII syntax:
REFERENCESTATIONTIMEOUT option [timeout]
Factory default:
REFERENCESTATIONTIMEOUT AUTO
ASCII example:
REFERENCESTATIONTIMEOUT SET 90
|
Field |
Field type |
ASCII value |
Binary value |
Description |
Format |
Binary bytes |
Binary offset |
|---|---|---|---|---|---|---|---|
|
1 |
Command header |
- |
- |
REFERENCESTATIONTIMEOUT header This field contains the command name for abbreviated ASCII or the message header for ASCII or Binary. |
- |
H |
0 |
|
2 |
option |
AUTO |
1 |
Sets the Timeout to 90 seconds1 The Timeout field is optional for AUTO and has no effect |
Enum |
4 |
H |
|
SET |
2 |
Must set the timeout value using the Timeout field 0 is not accepted when using the SET option |
|||||
|
3 |
timeout |
1 to 3600 s |
Specify the time |
Ulong |
4 |
H+4 |
|