PTPMODE

Enable or Disable the PTP Clock

Platform: 

OEM729, OEM7600, OEM7700, OEM7720, PwrPak7, CPT7, CPT7700, SMART7-I, SMART7-SI

Use this command to enable or disable the Precision Time Protocol (PTP) clock and configure the receiver's mode of operation.

Message ID: 2460

Abbreviated ASCII Syntax:

PTPMODE <ptp_mode>

Factory Default Setting:

PTPMODE DISABLE

ASCII Example:

PTPMODE ENABLE

Field

Field Type

ASCII Value

Binary Value

Description

Format

Binary Bytes

Binary Offset

1

Command header

PTPMODE header

This field contains the command name for abbreviated ASCII or the message header for ASCII or Binary.

H

0

2

ptp_mode

DISABLE

0

Disable the PTP clock module.

Enum

4

H

ENABLE

3

Enable standard operating mode with PTP functionality.

ENABLE_FINETIME

4

PTP functionality is enabled only after the receiver obtains GNSS time (GPS reference time status is FINESTEERING). Until that time, the PTP functionality remains idle. If the receiver loses FINESTEERING, PTP functionality continues. The deferral of PTP start up, if it occurs, only happens when the feature is enabled.