PPPSOURCE

Specifies the PPP correction source

Platform:

OEM719, OEM729, OEM7500, OEM7600, OEM7700, OEM7720, PwrPak7, CPT7, CPT7700, SMART7, SMART2

This command determines what corrections the PPP filter can use.

PPPSOURCE NONE disables PPP output.

Message ID: 1707

Abbreviated ASCII Syntax:

PPPSOURCE source

Factory Default:

PPPSOURCE auto

ASCII Example:

PPPSOURCE none

Field

Field Type

ASCII Value

Binary Value

Description

Format

Binary Bytes

Binary Offset

1

Command header

-

-

PPPSOURCE header

This field contains the command name for abbreviated ASCII or the message header for ASCII or Binary.

-

H

0

2

source

NONE

0

Disable PPP output

Enum

4

H

TERRASTAR

1

Only accept TerraStar PPP corrections

VERIPOS

2

Only accept Veripos PPP corrections

AUTO

100

Automatically select and use the best corrections