PPPDYNAMICS
Sets the PPP dynamics mode
Platform: |
OEM719, OEM729, OEM7500, OEM7600, OEM7700, OEM7720, PwrPak7, CPT7, CPT7700, SMART7, SMART2 |
This command configures the dynamics assumed by the PPP filter. AUTO detects the antenna dynamics and adapts filter operation accordingly.
The automatic dynamics detection may be fooled by very slow, “creeping” motion, where the antenna consistently moves less than 2 cm/s. In such cases, the mode should explicitly be set to DYNAMIC.
Message ID: 1551
Abbreviated ASCII Syntax:
PPPDYNAMICS mode
Factory Default:
PPPDYNAMICS dynamic
ASCII Example:
PPPDYNAMICS auto
Field |
Field Type |
ASCII Value |
Binary Value |
Description |
Format |
Binary Bytes |
Binary Offset |
1 |
Command header |
- |
- |
PPPDYNAMICS header This field contains the command name for abbreviated ASCII or the message header for ASCII or Binary. |
- |
H |
0 |
2 |
Mode |
AUTO |
0 |
Automatically determines dynamics mode |
Enum |
4 |
H |
STATIC |
1 |
Static mode |
|||||
DYNAMIC |
2 |
Dynamic mode |