PPPBASICCONVERGEDCRITERIA

Configures decision for PPP Basic convergence

Platform:

OEM719, OEM729, OEM7500, OEM7600, OEM7700, OEM7720, PwrPak7, CPT7, CPT7700, SMART7, SMART2

The PPPBASICCONVERGEDCRITERIA command sets the threshold that determines if the solution has converged for lower accuracy PPP solutions. These are the PPP solutions reported with the PPP_BASIC and PPP_BASIC_CONVERGING position types.

The convergence threshold for high-accuracy PPP solutions (reported with PPP and PPP_CONVERGING position types) is set using the PPPCONVERGEDCRITERIA command.

Relaxing the convergence threshold shortens the time before a PPP solution is reported as converged. However, it does not alter solution behavior. During the initial PPP solution period, the positions can have decimetre error variation. Only relax the convergence threshold if the application can tolerate higher solution variability.

Message ID: 1949

Abbreviated ASCII syntax:

PPPBASICCONVERGEDCRITERIA criteria tolerance

Factory default:

PPPBASICCONVERGEDCRITERIA horizontal_stddev 0.60

ASCII example:

PPPBASICCONVERGEDCRITERIA total_stddev 0.45

Field

Field type

ASCII value

Binary value

Description

Format

Binary bytes

Binary offset

1

Command header

-

-

PPPBASICCONVERGEDCRITERIA header

This field contains the command name for abbreviated ASCII or the message header for ASCII or Binary.

-

H

0

2

Criteria

TOTAL_STDDEV

1

Use the total, 3D, standard deviation

Enum

4

H

HORIZONTAL_STDDEV

2

Use the horizontal, 2D, standard deviation

3

Tolerance

 

 

Tolerance (m)

Float

4

H+4