POSTIMEOUT
Sets the position time out
|
Platform: |
OEM719, OEM729, OEM7500, OEM7600, OEM7700, OEM7720, PwrPak7, CPT7, CPT7700, SMART7, SMART2 |
This command is used to set the time out value for the position calculation in seconds.
In position logs, for example BESTPOS log or PSRPOS log, when the position time out expires, the Position Type field is set to NONE. Other field values in these logs remain populated with the last available position data. Also, the position is no longer used in conjunction with the almanac to determine what satellites are visible.
Message ID: 612
Abbreviated ASCII syntax:
POSTIMEOUT sec
Factory default:
POSTIMEOUT 600
ASCII example:
POSTIMEOUT 1200
When performing data collection in a highly dynamic environment (for example, urban canyons or in high speed operations), you can use POSTIMEOUT to prevent the receiver from outputting calculated positions that are too old. Use POSTIMEOUT to force the receiver position type to NONE. This ensures that the position information being used in the BESTPOS log or PSRPOS log is based on a recent calculation. All position calculations are then recalculated using the most recent satellite information.
|
Field |
Field type |
ASCII value |
Binary value |
Description |
Format |
Binary bytes |
Binary offset |
|
1 |
Command header |
- |
- |
POSTIMEOUT header This field contains the command name for abbreviated ASCII or the message header for ASCII or Binary. |
- |
H |
0 |
|
2 |
sec |
0-86400 |
Time out in seconds |
Ulong |
4 |
H |
|