POSTIMEOUT

Sets the position time out

Platform:

OEM719, OEM729, OEM7500, OEM7600, OEM7700, OEM7720, PwrPak7, CPT7, CPT7700, SMART7, SMART2

This command is used to set the time out value for the position calculation in seconds.

In position logs, for example BESTPOS log or PSRPOS log, when the position time out expires, the Position Type field is set to NONE. Other field values in these logs remain populated with the last available position data. Also, the position is no longer used in conjunction with the almanac to determine what satellites are visible.

Message ID: 612

Abbreviated ASCII syntax:

POSTIMEOUT sec

Factory default:

POSTIMEOUT 600

ASCII example:

POSTIMEOUT 1200

When performing data collection in a highly dynamic environment (for example, urban canyons or in high speed operations), you can use POSTIMEOUT to prevent the receiver from outputting calculated positions that are too old. Use POSTIMEOUT to force the receiver position type to NONE. This ensures that the position information being used in the BESTPOS log or PSRPOS log is based on a recent calculation. All position calculations are then recalculated using the most recent satellite information.

Field

Field type

ASCII value

Binary value

Description

Format

Binary bytes

Binary offset

1

Command header

-

-

POSTIMEOUT header

This field contains the command name for abbreviated ASCII or the message header for ASCII or Binary.

-

H

0

2

sec

0-86400

Time out in seconds

Ulong

4

H