PDPMODE

Selects the PDP mode and dynamics

Platform:

OEM719, OEM729, OEM7500, OEM7600, OEM7700, OEM7720, PwrPak7, CPT7, CPT7700, SMART7, SMART2

This command is used to select the mode and dynamics of the PDP filter.

The PDPFILTER ENABLE command (see the PDPFILTER command) must be entered before the PDPMODE command.

It is recommended that the ionotype be left at AUTO when using either normal mode PDP or GLIDE. See also the SETIONOTYPE command.

Message ID: 970

Abbreviated ASCII Syntax:

PDPMODE mode dynamics

Factory Default:

PDPMODE normal auto

ASCII Example:

PDPMODE relative dynamic

Field

Field Type

ASCII Value

Binary Value

Description

Format

Binary Bytes

Binary Offset

1

Command header

-

-

PDPMODE header

This field contains the command name for abbreviated ASCII or the message header for ASCII or Binary.

-

H

0

2

mode

NORMAL

0

In RELATIVE or GLIDE mode, GLIDE performance is optimized to obtain a consistent error in latitude and longitude over time periods of 15 minutes or less, rather than to obtain the smallest absolute position error. See also GLIDE Position Filter for GLIDE mode additional information.

GLIDE mode is the same as RELATIVE mode.

Enum

4

H

RELATIVE

1

GLIDE

3

3

dynamics

AUTO

0

Auto detect dynamics mode

Enum

4

H+4

STATIC

1

Static mode

DYNAMIC

2

Dynamic mode