NMEABEIDOUTALKER

Sets the NMEA BeiDou talker ID

Platform:

OEM719, OEM729, OEM7500, OEM7600, OEM7700, OEM7720, PwrPak7, CPT7, CPT7700, SMART7, SMART2

This command is used to alter the behavior of the NMEA BeiDou talker ID. The default behavior is to use the legacy BeiDou Talker ID of 'BD' to maintain backward compatibility.

Message ID: 2258

Abbreviated ASCII Syntax:

NMEABEIDOUTALKER id

Factory Default:

NMEABEIDOUTALKER BD

ASCII Example:

NMEABEIDOUTALKER GB

Field

Field Type

ASCII Value

Binary Value

Description

Format

Binary Bytes

Binary Offset

1

Command header

NMEABEIDOUTALKER header

This field contains the command name for abbreviated ASCII or the message header for ASCII (see page 1) or Binary (see page 1).

H

0

2

id

GB

0

Use the NMEA ID

Enum

4

H

BD

1

Use the legacy ID