FORCEGALE6CODE
Force receiver to track Galileo E6C or E6B signal
Platform: OEM719, OEM729, OEM7700, PwrPak7, CPT7700
Use this command to force Galileo E6 channels to track E6B or E6C.
Message ID: 2222
Abbreviated ASCII Syntax:
FORCEGALE6CODE E6codetype
Factory Default:
FORCEGALE6CODE E6B
Field |
Field Type |
ASCII Value |
Binary Value |
Description |
Format |
Binary Bytes |
Binary Offset |
---|---|---|---|---|---|---|---|
1 |
Command header |
- |
- |
FORCEGALE6CODE header This field contains the command name for abbreviated ASCII or the message header for ASCII (see page 1) or Binary (see page 1). |
- |
H |
0 |
2 |
E6codetype |
E6B |
0 |
Galileo E6 code type (default = E6B) |
Enum |
4 |
H |
E6C |
1 |