FORCEGALE6CODE

Force receiver to track Galileo E6C or E6B signal

Platform: OEM719, OEM729, OEM7700, PwrPak7, CPT7700

Use this command to force Galileo E6 channels to track E6B or E6C.

Message ID: 2222

Abbreviated ASCII Syntax:

FORCEGALE6CODE E6codetype

Factory Default:

FORCEGALE6CODE E6B

Field

Field Type

ASCII Value

Binary Value

Description

Format

Binary Bytes

Binary Offset

1

Command header

-

-

FORCEGALE6CODE header

This field contains the command name for abbreviated ASCII or the message header for ASCII (see page 1) or Binary (see page 1).

-

H

0

2

E6codetype

E6B

0

Galileo E6 code type

(default = E6B)

Enum

4

H

E6C

1