DOPPLERWINDOW
Change the behavior of the doppler search
Platform: |
OEM719, OEM729, OEM7500, OEM7600, OEM7700, OEM7720, PwrPak7, CPT7, CPT7700, SMART7, SMART2 |
Change the behavior of the doppler search for automatic channel assignments in the receiver. This command is used where the SV doppler may be outside of the normal receiver doppler search window of +/-16000 Hz.
The DOPPLERWINDOW command should only be used by advanced users.
Message ID: 1512
Abbreviated ASCII Syntax:
DOPPLERWINDOW system setting doppler_window
Factory Default:
DOPPLERWINDOW ALL AUTO 0
ASCII Example:
DOPPLERWINDOW GPS USER 20000
Field |
Field Type |
ASCII Value |
Binary Value |
Description |
Format |
Binary Value |
Binary Offset |
---|---|---|---|---|---|---|---|
1 |
Command header |
– |
– |
DOPPLERWINDOW header This field contains the command name for abbreviated ASCII or the message header for ASCII or Binary. |
– |
H |
0 |
2 |
system |
Satellite system to configure. |
Enum |
4 |
H |
||
3 |
setting |
AUTO |
0 |
Doppler window mode |
Enum |
4 |
H+4 |
USER |
1 |
||||||
4 |
doppler_window |
0 to 50000 |
Doppler window to search in Hz |
Ulong |
4 |
H+8 |
|
5 |
Reserved |
Long |
4 |
H+12 |