BESTVELTYPE

Sets the velocity used in the BESTVEL and GPVTG logs

Platform:

OEM719, OEM729, OEM7500, OEM7600, OEM7700, OEM7720, PwrPak7, CPT7, CPT7700, SMART7, SMART2

This command configures the source of the velocity that is output in the BESTVEL and GPVTG logs. Set the type to something other than BESTPOS when an unchanging velocity source with specific characteristics is needed.

The Doppler velocity is the highest-availability, lowest-latency velocity available from the receiver. Due to its low latency, it is also the noisiest velocity.

When the RADARCONFIG command is enabled, the BESTVELTYPE mode is set to DOPPLER.

Message ID: 1678

Abbreviated ASCII Syntax:

BESTVELTYPE mode

Factory Default:

BESTVELTYPE bestpos

ASCII Example:

BESTVELTYPE doppler

Field

Field Type

ASCII Value

Binary Value

Description

Format

Binary Bytes

Binary Offset

1

Command header

BESTVELTYPE header

This field contains the command name for abbreviated ASCII or the message header for ASCII (see page 1) or Binary (see page 1).

-

H

0

2

mode

BESTPOS

1

Use the velocity from the same positioning filter that is being used to fill BESTPOS and GPGGA.

Enum

4

H

DOPPLER

2

Always fill BESTVEL and GPVTG using Doppler-derived velocities.